You are here:

Computer spirometer MAS2-PC

Computer spirometer stationary spiroanalyzer
Software IntelSpiro Asthma Monitor
Software IntelSpiro Medical examination Screening
Pulse Oximetry Mode
Integration with hospital information system (HIS) (E-Health)
Animation test
GLI-2012
Spirometry standardization
STB
Declaration of Conformity EAEU
RST
SKT
Certificate of conformity
ISO Manufacturing Certificate

Computer spirometer MAS2-PC

Additional equipment:

    Pulse Oximetry
    IntelSpiro:Screening
    IntelSpiro:Asthma-monitor
    Remote collection and analysis of spirograms
    Integration with HIS
    Calibration device
    Printing device
    Laptop / PC

    Number of disposable mouthpieces:
    Number of reusable mouthpieces:
    Number of nose clips:
    Number of disposable bacterial viral filters:





    Organization type?






    I want to receive company news

    Your data will not be passed on to third parties

    Applicability of MAS2-PC spirometer:

    – Specialized diagnostic centers;
    – Departments of functional diagnostics;
    – Pulmonology departments;
    – Healthcare institutions of the 3rd and 4th levels;
    – Scientific research;
    – In the process of training.

    Key features of the MAS2-PC spirometer:

    • Classical spirometry
    • Pre-post tests (3 protocols)
    • Evaluation of respiratory function “at a glance”
    • Assessment of the quality of tests: ATS – 1994, ATS/ERS – 2005, ATS/ERS – 2019
    • Dynamic observation for routine spirometry for children – “Children’s Monitor
    • Dynamic observation in routine spirometry for adults – “COPD Monitor”
    • Animation test (for children and hearing impaired)
    • Transferring spirometry data to a PC
    • Forming respiratory risk groups during medical and clinical examinations
    • Electronic questionnaires: ACTtm, CATtm
    • Comparison, regression, dynamic monitoring modes
    • Software for remote collection and analysis of spirograms
    • Remote software update
    • Patient data recording to USB flash drive.

    MAS2-PC computer storage Spirometer is connected to a personal computer (PC), on which the IntelSpiro expert software is installed. The desktop spiroanalyzer is an intelligent measuring and information system that allows performing all the classic spirometric maneuvers with automatic quality control. A number of stored protocols of spirometric studies is limited only by the capacity of the PC drive. To improve the accuracy of measurements during large numbers of examinations (for example, during professional examinations), the spirometer uses a pneumotachometric respiration sensor (Fleisch tube) with temperature control.

    MAS2-PC allows automatic assessment of the respiratory system state with the issuance of an automatic syndromic conclusion based on the measurement of external respiration. It is allowed to use both reusable and disposable mouthpieces and antibacterial filters.

    Specifications MAS2-PC

    Characteristic Meaning
    Screen Used PC monitor
    Keyboard Used PC keyboard
    Built-in weather station for BTPS correction Measurement of temperature, humidity, pressure.
    E-Health Integration with medical information systems (e-health, HIS), connection to local networks.
    PC connection interface USB
    Supported OS MS Windows version XP, 7, 8, 8.1, 10
    Database Capacity (number of records) Limited by PC memory
    Sensor type pneumotachometric respiration sensor (Fleisch tube)
    BTPS correction automatic
    Inhale / Exhale Yes / Yes
    Flow range, l/s ±16 ±3%
    Volume range, l 0.2/0.8 – 8 ±3%
    Automatic test quality control Yes, ATS-1994, ATS/ERS-2005, ATS/ERS-2019
    Animation test Yes
    Spirometry
    VC test
    FVC, TV, MV, ERV, IRV, BF, IC, EVC, IVC quality criteria: Nvc, ΔVC, VFOT
    Spirometry
    FVC test
    FVC, FEV1, %FVC, %VC, PIF,PEF, MEF25, MEF50, MEF75, FEF25-75, FEV0.5, FEV0.75, FEV3, FEV0.75/VC, FEV0.75/FVC, FEV3/VC, FEV3/FVC, FIVC, FIV1, FIV1/FIVC, MIF25, MIF50, MIF75, MET, FET, MTT, TPEF,
    TPEF/FET, FEV0.2-1.2, FEV75-85, FEVpef Sfvc, MEF50/FVC, MEF50/VC, Тμ0, Тμ1, Тμ2, VC/FEFpef
    – quality criteria: Nfvc, ΔFVC, ΔFEV1, EV, VeotFVC.
    Spirometry
    MVV test
    MVV, TVm, RRm, VC/MVV
    Test АСТ™, САТ™ Yes
    Bronchodilator test Yes
    Functional test Yes
    Comparison 2, multiple measurement, regression, dynamic observation
    Reference values Up to 9 systems for 3 to 95 years (Klement, ECCS – European Coal and Steel Society,Knudson, GLI-2012 – adults; Shiryaeva, Knudson, Quanjer, Zapletal, GLI-2012 – children). Automatic age- and race- dependent system selection.
    Pulse Oxymetry option
    Parameters TV, MV, BF, SpO2avrg, SpO2min, SpO2max, HFavrg, HFmin, HFmax, PIavrg, PImin, PImax
    SpO2 range 35-100%
    Heart rate range (HF) 30-240 beat/min
    Software “Screening” (medical examination) option
    Software “Asthma-monitor” option
    Asthma-monitor
    Peakflowmetry test
    PEF and FEV1, daily variability (DV)
    Printer type, connection, protocol format Any external printer, compatible with Windows, via port PC, A4
    Paper type A4, office paper
    Types of printed protocols Spirometry reports:
    basic (1 page), advanced (2 pages);
    Tests protocols:
    – bronchodilator test report (pre/post)
    – functional test report
    “Screening” (option)
    “Asthma-monitor” (option)
    Size, mm, max (without flow sensor) 225x177x46
    Weight, g, max 650